OVER 10 YEARS OF EXPERIENCE
FREE SHIPPING FROM € 150,- ORDER VALUE (GER)

LED ECG Driver 350mA - 700 mA

LED ECG Driver 350mA - 700 mA

LED ECG - Electronic ballasts for 350mA - 700mA Driver

  • LED ECG (LED driver) for 350mA to 700mA in various performances.
  • As single unit with fixed setting only for 350mA is the most commonly used constant current. (1W-LEDs)
  • ECG LEDs for 700mA are commonly used with 2W power LEDs.
  • Choice of a large number of individual devices with fixed settings or programmable constant current with preset values (350mA, 500mA, 600mA, 700mA, 900mA, 1050mA and more) via dipswitch are affordably available here.
  • Different performance classes (15W to 80W), as well as dimmable via 1..10V, DALI or push button, Zigbee, Casambi can be found here in this category. We are happy to help you to select your LED ECG (= LED Driver = constant current source).

 

You want to….

learn more about LED ECG, LED Driver 350 mA, LED Driver 700 mA

LED ECG - Electronic ballasts for 350mA - 700mA Driver LED ECG (LED driver) for 350mA to 700mA  in various performances. As single unit with fixed setting only for... read more »
Close window

LED ECG - Electronic ballasts for 350mA - 700mA Driver

  • LED ECG (LED driver) for 350mA to 700mA in various performances.
  • As single unit with fixed setting only for 350mA is the most commonly used constant current. (1W-LEDs)
  • ECG LEDs for 700mA are commonly used with 2W power LEDs.
  • Choice of a large number of individual devices with fixed settings or programmable constant current with preset values (350mA, 500mA, 600mA, 700mA, 900mA, 1050mA and more) via dipswitch are affordably available here.
  • Different performance classes (15W to 80W), as well as dimmable via 1..10V, DALI or push button, Zigbee, Casambi can be found here in this category. We are happy to help you to select your LED ECG (= LED Driver = constant current source).

 

You want to….

learn more about LED ECG, LED Driver 350 mA, LED Driver 700 mA

3 From 8
No results were found for the filter!
Universale 20 device
Universale 20 Low Current Konverter RIPPLE FREE
  • 0,35A, 0,5A, 0,55A, 0,7A, 0,25A, 0,4A, 0,45A, 0,6A
  • 5 - 20 W
25.83€ *
Order number: T20-122201

Delivery time 3-5 workdays*

see Details
TCI Mini MD
TCI driver Mini MD / Mini MD BI
  • Linear/AM, Phase-Cut (Triac)
  • 0,35A, 0,5A, 0,7A
  • 5 - 20 W
24.79€ *
Order number: 760-127030

Ready to ship today,
Delivery time appr. 1-3 workdays*

see Details
TCI Pro Flat LC DALI
TCI Pro Flat LC DALI
  • DALI, Linear/AM, Push-Button
  • 0,2A, 0,35A, 0,5A, 0,25A, 0,4A, 0,45A, 0,3A, 0,22A, 0,38A, 0,1A, 0,18A
  • 20 - 50 W, 5 - 20 W
44.10€ * 49.00€ *
Order number: 1481-127600

Ready to ship today,
Delivery time appr. 1-3 workdays*

see Details
PCD-25 Meanwell product picture
Meanwell PCD25 Powersupplies dimmable
  • Phase-Cut (Triac)
  • 0,35A, 0,7A, 1,05A, 1,4A
  • 20 - 50 W, 5 - 20 W
21.54€ *
Order number: PCD25-350B

Delivery time 3-5 workdays*

see Details
LED Netzteil Abmessungen zu Casambi inside
Multi-LED power supply with Casambi Inside
  • Casambi radio, Push-Button, BT4.0 (2,4 GHz)
  • 0,35A, 0,5A, 0,7A
  • 20 - 50 W, 5 - 20 W
111.10€ *
Order number: 800578

Delivery time 2-4 workdays*

see Details
XLG-25-A und XLG-25-AB
Meanwell XLG-25 power supply
  • XLG
  • 1..10V, PWM
  • 0,7A
  • 20 - 50 W, 5 - 20 W
Variants from 24.63€ *
Order number: XLG25-A

Delivery time 5-10 workdays*

see Details
DALI LED Power Supply CW-WW (DT8)
DALI LED Power Supply CW-WW (DT8)
  • DALI, DALI DT8
  • Tuneable White
  • 1,0A, 0,35A, 0,5A, 0,7A, 0,8A
  • 20 - 50 W, 5 - 20 W
Variants from 68.39€ *
Order number: L89453849-CWW-700

Delivery time 2-4 workdays*

see Details
TCI Pro Flat DALI 26
TCI Pro Flat DALI 26
  • DALI, Linear/AM, Push-Button, DALI2
  • 0,5A, 0,55A, 0,65A, 0,7A, 0,25A, 0,4A, 0,45A, 0,6A, 0,3A, 0,26A, 0,34A, 0,38A
  • 20 - 50 W, 5 - 20 W
45.94€ *
Order number: 6402-127576

Ready to ship today,
Delivery time appr. 1-3 workdays*

see Details
127370, 127372, ATON DALI
ATON DALI 30W 250-700mA
  • DALI, Linear/AM, Push-Button, DALI2
  • 0,5A, 0,55A, 0,65A, 0,7A, 0,25A, 0,4A, 0,45A, 0,6A, 0,26A, 0,34A, 0,38A
  • 20 - 50 W, 5 - 20 W
61.76€ *
Order number: 804-127370

Delivery time 1-3 weeks*

see Details
TCI LED driver with Casambi module for conductor rail
TCI LED driver with Casambi module for...
  • Casambi radio
  • 0,35A, 0,5A, 0,55A, 0,65A, 0,7A, 0,4A, 0,45A, 0,6A
  • Power rail
  • 20 - 50 W
109.94€ *
Order number: 6643-127634

Delivery time 4-6 weeks*

see Details
LED Converter Jolly MD application
Dimmable LED Converter Jolly MD PUSH
  • Phase-Cut (Triac), Push-Button
  • 0,35A, 0,5A, 0,55A, 0,7A, 0,75A
  • 20 - 50 W, 5 - 20 W
40.48€ *
Order number: 224-122260

Ready to ship today,
Delivery time appr. 1-3 workdays*

see Details
Jolly Slim 123680
TCI JOLLY 1...10 V & PUSH - Slim LED driver
  • 1..10V, Push-Button
  • 0,35A, 0,5A, 0,7A
  • 20 - 50 W, 5 - 20 W
42.30€ *
Order number: 123680

Delivery time 3-5 workdays*

see Details
3 From 8

How it all started with 350mA ECGs for LED!

The breakthrough of LEDs began with the so-called power LEDs. These were "energized" with 350mA. Many users spoke of the "1W operation" of a LED. Higher currents were not usual for the service life and necessary heat dissipation. The demand for LED drivers with 350mA current is correspondingly high.

Yes, they began to connect LEDs in series. Thus, several LEDs could be operated via a 350mA ECG. But more than eight LEDs were rare. 350mA LED ECG with max. output voltage higher than 24V was taboo.

Today, LEDs with 350mA are still popular. This ensures low heat development, higher efficiency and longer lifetime than operating a LED driver with constant currents of 700mA or higher..

The worry of higher output voltage is also a thing of the past.

For example, with the 350mA LED driver Maxi Jolly HV 127414 it is possible to efficiently operate 30 LEDs in series on one string.

Skeptics fear that if one LED fails, the entire LED chain will fail. Experience has shown that LEDs, due to their nature and internal protective diodes, end in a short circuit in 95% of cases in the event of a defect.

So the current can continue to flow and only this one LED is perceived as faulty at most.

Wherever sustainability, long lifetime and reliability are important, LEDs still like to be driven by 350mA LED drivers. Especially the street lighting sector still likes to use LED drivers in 350mA operation.

Why LED ballast with 700mA constant current?

In the early beginnings of LED, low-power LEDs were used. Usually 10mA constant current was used for one light emitting diode. This was mostly realized by using a series resistor of approx. 270Ohm for operation at 5V. With a forward voltage of approx. 2. 5V and a current of approx. 10mA at the series resistor, the missing 2. 5V dropped off.

Around 2009, a power of 1W could be converted into light by using so-called power LEDs at a current of 350mA. The constant current control by means of a series resistor would have become true heaters. Accordingly, the constant current via pulse width modulation (PWM) was used in modern LED drivers via clocked controllers.

Operation with 350mA was almost standard.

Today with more and more powerful LEDs it is no longer a problem. Even currents of >1A with appropriate heat dissipation bring an excellent price-performance ratio.

LED drivers are often set to 700mA as a good compromise. This corresponds to a power of approximately 2. 5W per LED.

Effect of the currents on the LED

Small currents for a LED mean:

  • Low heating
  • Long lifetime
  • High luminous efficacy
  • Possibly worse cost-benefit ratio

Doubling the current with LED driver 700mA

  • Higher LED operating temperature, as internal temperature difference (RthJC) doubles
  • This reduces the lieftime (per 10K - halving of the lifetime)
  • Fewer LEDs for the same light --> lower costs, less manufacturing effort

In the meantime, more and more current sources with 700mA are being used, as LED technology has improved considerably in recent years.

ECGs for LED currents of 700mA are now widely used. In the above selection you will find a variety of LED ECGs, which can be set to 700mA via dip-switches.

It goes without saying that these two values are not mandatory. Currents of 500mA are also used with pleasure.

Viewed
LED Service 4 U

LED-TECHNIK PUR

You can find even more knowledge, experience reports and test series in our
LED knowledge blog
Here we have created many helpful contributions illustriously and informatively.

Satisfied with website information, advice and products?

Then please give us a few stars at Googlegoogle stars